Typical Wall cut-view
Masonry wall with metal veneer.

Masonry wall with metal veneer. Sprayed from the exterior.
Wall components R S I R
  Metric Imperial
1 Outside air film 0.03 0.17
2 Metal panel / /
3 " Z " Bar / /
4 Air space 0.17 0.97
5 Sprayed polyurethane foam HEATLOK 0240 See See
below below
6 Concrete Bloc 200mm / 8 " 0.18 1.11
7 Inside air film 0.12 0.68
Basic thermal resistance value without spray-applied foam 0.50 2.93
 
System performance - Metric / Imperial
Insulation thickness HEATLOK 0240 38 mm * 1 1/2" 51 mm * 2" 64 mm *
2 1/2"
76 mm * 3" 89 mm *
3 1/2"
Insulation RSI / R value 1.58 * 9 2.10 * 12.0 2.64 * 15.0 3.16 * 18.0 3.69 * 21.0
Total wall resistance value 2.08 * 11.93 2.60 * 14.93 3.14 * 17.93 3.66 * 20.93 4.19 * 23.93
 

  1. ( Typical Wall cut-view : Aluminum or vinyl siding on framewood. )