Typical Wall cut-view
Masonry wall with brick veneer

Masonry wall with brick veneer. Sprayed from the exterior
Wall components R S I R
  Metric Imperial
1 Outside air film 0.03 0.17
2 Brick siding 0.08 0.44
3 Air space 0.17 0.97
4 Sprayed polyurethane foam HEATLOK 0240 See See
below below
5 Concrete Bloc 200mm / 8 " 0.18 1.11
6 Inside air film 0.12 0.68
Basic thermal resistance value without spray-applied foam 0.58 3.37
 
System performance - Metric / Imperial
Insulation thickness HEATLOK 0240 38 mm * 1 1/2" 51 mm * 2" 64 mm *
2 1/2"
76 mm * 3" 89 mm *
3 1/2"
Insulation RSI / R value 1.58 * 9 2.10 * 12.0 2.64 * 15.0 3.16 * 18.0 3.69 * 21.0
Total wall resistance value 2.16 * 12.37 2.68 * 15.37 3.22 * 18.37 3.74 * 21.37 4.27 * 24.37
 

  1. ( Typical Wall cut-view : Aluminum or vinyl siding on framewood. )
  2. ( Typical Wall cut-view : Masonry wall with brick veneer. )
  3. ( Typical Wall cut-view : Masonry wall with metal veneer. )  
  4. ( Return : Menu / Architectural conceptions. )